Products cartec
product
OEM Recommendations

CET 2200 C - Emission analyser for Petrol and Diesel engines
Product Description:
Type approvals in several countries.
- Compatible to E-OBD standard
- Measurement CO, HC, CO2, O2 - NOx optional
- Lambda calculation
- Petrol RPM measurement with RPM pincers or RPM antenna
- Oil temperature measurement by oil temperature sensor
- Smoke cell with partial flow measurement
- User's guide via colour display
- Possible input of customer and vehicle specific data
- Automatic message when maintenance work is required
- 4 interfaces RS-232
- Integrated data printer
Measuring range and measuring accuracy:
- CO:
- Range 0-14 Vol.% / Resolution 0,001 (up to 9,999) (0,01 at 10 - 14 Vol.%)
- at 0-9,999 Vol.% = +/- 0,01 Vol.% or 3% of measured value
- 10 - 14 Vol.% +/- 5% of measured value
- CO2:
- Range 0,00 - 18 Vol.% / Resolution 0,01 Vol.%
- +/- 0,3 Vol.% or 3 % of measured value
- HC:
- Standard: Range 0-9999 Vol. ppm / Resolution 1 ppm
- Optional: Range 0-20,000 Vol. ppm / Resolution 1 ppm
- 0-2000 Vol. ppm +/- 4 Vol. ppm or 3 % of measured value
- 2000-5000 Vol. ppm +/- 5 % of measured value
- Standard: 5000-9999 Vol. ppm +/- 10 % of measured value
- Optional: 5000-20,000 Vol. ppm +/- 10 % of measured value
- O2:
- Range 0,00 - 25 Vol.% / Resolution 0,01 Vol.%
- +/- 0,1 Vol.% or 5 % of measured value
- NO:
- Range 0-9999 Vol. ppm Resolution 1 ppm
- > 10 % of measured value
- Opacity:
- Opacity % 0 - 100
- Opacity K (1/m) 0 - 9,99
- Accuracy ± 2% at max. value
- 0,01 = Resolution
Characteristics:
- assessment of opacity with free acceleration acc. to EO-18-10
- assessment of opacity by the continous ECE-R24 test method
- non-dispersive infrared method (NDIR)
- infrared measuring bench for CO, CO2 and HC
- electro chemical NOx and O2
- pressure and temperature compensated
- smoke test cell for partial flow measurement at the exhaust pipe
- meets OIML "0" standard
Power consumption (W)60 - 140
Warm-up time max. (min)2
Warm-up time max. smoke cell (min)10
Humidity (%)-90
Pressure adjustmentautomatic
Exhaust probe hose (m)8
Emission fine filter (µm)5
Emission coarse filter (µm)5
Water filter (µm)10
Board voltage230 V / 50-60 Hz
Temperature range (°C)5 - 40
Trolley (kg)26
Smoke cell - Width (mm)150
Smoke cell - Height (mm)410
Smoke cell - Depth (mm)235
Smoke cell - Weight (kg)13
Display unit Height (mm)240
Display unit Width (mm)510
Display unit Depth (mm)480
Display unit Weight (kg)24
- EOBD connector (SAE 1962)
- Trolley with console for book and keyboard
- Cable bracket for trolley
- Infrared remote control unit
- RPM-counter optical
- Single cylinder measurement for motorcycles
- NOx-measurement electrochemical
- RPM antenna
- Interface for ASA-Network
- Emission tester CET 2200
- Smoke cell
UDA 4500
Can be adapted to all types of diesel and petrol exhaust gas analysers
UDA 8000
Can be adapted to all types of diesel and petrol exhaust gas analysers, Integrated power supply (rechargeable batteries), Perfectly legible LC display with two lines of 16 characters each, Contrary to UDA 4500 there are more adaptors
CET 2200 B
Measurement of CO, HC, CO2, O2 (NOx optional), connectable to PC-based network reporting systems, RS 232 interfaces for extensions, LPT socket for external parallel printer - Type approvals in several countries
CET 2200 D
Opacity test according to ECE-R-24 (free acceleration), connectable to PC-based network reporting systems, RS 232 interfaces for extensions, LPT socket for external parallel printer - Type approvals in several countries